Locations:
Search IconSearch

Reduced-Radiation Ablation for Pediatric Tachyarrhythmias

Emerging data offer reassurance of uncompromised efficacy

690×380-Reduced-Radiation

ablatBy Peter F. Aziz, MD

Advertisement

Cleveland Clinic is a non-profit academic medical center. Advertising on our site helps support our mission. We do not endorse non-Cleveland Clinic products or services. Policy

As fewer than 9 percent of pediatric cardiologists specialize in electrophysiology, research is essential to advancing knowledge in this subspecialty discipline. Cleveland Clinic Children’s Center for Pediatric and Congenital Heart Disease has a range of electrophysiology-related research projects underway.

One of them, profiled here, has yielded results with the potential to impact treatment of children with tachyarrhythmias by providing reassurance that radiation exposure can be curbed or eliminated during catheter ablation procedures without compromising efficacy.

Catheter ablation with minimal to no fluoroscopy

The risks of radiation exposure are dose-dependent and cumulative over time, which makes reduction of radiation exposure in pediatric patients highly desirable. Radiation exposure can be decreased during catheter ablation with a relatively new technique using a 3-D electroanatomical navigation system. Major cardiac structures are mapped and used as reference points for tracking the location of the ablation catheter with magnets (Figure).

Reduced-radiation ablation for tachyarrhythmias

Figure. A snapshot of our “interface” of imaging using the 3-D electroanatomical navigation system. Intracardiac electrical tracings are shown during an atrial arrhythmia, along with the 3-D anatomical image of the right atrium (a large version of which is shown at the top of this post). These tools are used simultaneously and provide an excellent map for use in targeting ablation.

The system allows right heart ablation to be performed without fluoroscopy. When an arrhythmia is generated on the left side, fluoroscopy and intracardiac echocardiography are used to perform the transseptal puncture. However, ablation can be performed without fluoroscopy.

Advertisement

Filling knowledge gaps with a case-control study

Because 3-D electroanatomical systems are relatively new, our understanding of their efficacy relative to that of conventional catheter ablation is still evolving. To fill gaps in that understanding, we reviewed the charts of 20 pediatric patients (mean age, 14.1 years) who underwent 3-D electroanatomical mapping for catheter ablations in the treatment of supraventricular tachyarrhythmias at Cleveland Clinic Children’s from October 2012 to May 2013.

All procedures were done by a single operator. Safety, efficacy and outcomes were compared with those of 20 age-matched control patients who underwent the same procedures by the same operator using conventional fluoroscopic guidance.

Although mean procedure time did not differ significantly between the two groups, mean fluoroscopy time was significantly lower with the 3-D mapping system (5.1 min) than with conventional fluoroscopic guidance (35.44 min) (P < .001). The average radiation dose was also significantly lower with 3-D mapping (7 mGy vs. 137.4 mGy; P < .0001). Twelve patients in the 3-D mapping group (60 percent) required no fluoroscopy use.

Acute procedural success was achieved in 18 of 20 patients in each group. Recurrence of the tachyarrhythmia was seen in only one patient in each group at follow-up.

We are currently adding more patients to this data set and will soon be publishing our full results.

New urgency to shift to reduced-radiation ablation

When we began this study in 2012, only about 1 in 50 electrophysiologists was using the 3-D mapping system to minimize fluoroscopy. Today, that number may be closer to 1 in 15.

Because the system’s manufacturer does not currently offer courses on using the system, I am training electrophysiologists in its use here at Cleveland Clinic Children’s. Our adult electrophysiology fellows frequently adopt this technique and take it to their new practice settings after they complete their training. I believe that the sooner this new system can be adopted, the more quickly we can reduce radiation exposure in our patients, young or old.

Dr. Aziz is a pediatric electrophysiologist in the Department of Pediatric Cardiology in the Center for Pediatric and Congenital Heart Disease.

Advertisement

Related Articles

woman giving subcutaneous self-injection in abdomen
Can Enoxaparin Be Used as a Bridge to Warfarin for Outpatients With LVADs?

Cleveland Clinic series supports its feasibility, especially with HeartMate 3

side-by-side procedural images of TAVR and SAVR
Valve-in-Valve TAVR vs. Redo SAVR for a Failed SAVR Bioprosthesis

Questions remain following late mortality signal from a retrospective cohort study

heart with female symbol overlay
Sex Disparities in Cardiac Care: Female Heart Surgeons Act for Change

How two of our surgeons are working for care equity, greater representation in research and practice

operating room during robotic heart surgery
Robotic Mitral Valve Repair: Reflections After 2,400-Plus Cases

Judicious application yields a 99.7% repair rate and 0.04% mortality

nutrition label of product containing xylitol
Another Sugar Substitute, Xylitol, Is Linked to Heightened Cardiovascular Risk

Studies reveal increased cardiac events, enhanced platelet reactivity and thrombotic potential

hypertrophied human heart
A Transaortic Approach to Midventricular and Apical Septal Myectomy

Large single-center series demonstrates safety and efficacy for extending procedure

woman doctor in white coat
Meet Dr. Amanda Vest, New Section Head of Heart Failure and Transplant Cardiology

Eminent clinician-researcher brings special expertise in nutritional interventions for heart failure

Ad