Case Study: Using Strain Echo to Recognize Cardiotoxicity from Cancer Therapy

New technology can help avoid a choice between cancer and heart disease

Strain-Ecco-690

By Juan Carlos Plana, MD

Advertisement

Cleveland Clinic is a non-profit academic medical center. Advertising on our site helps support our mission. We do not endorse non-Cleveland Clinic products or services. Policy

Presentation

A 47-year-old woman diagnosed with invasive ductal carcinoma of the breast (estrogen receptor-negative, progesterone receptor-positive, HER-2/neu-protein-positive) was started on treatment with docetaxel, carboplatin and trastuzumab in preparation for mastectomy.

Prior to chemotherapy initiation, baseline strain echocardiography was performed at Cleveland Clinic’s Cardio-Oncology Center, which revealed a left ventricular ejection fraction (LVEF) of 65 percent with global longitudinal strain of –25.5 percent (Figure 1).

Her follow-up echocardiogram three months after the start of trastuzumab-based chemotherapy showed a LVEF of 58 percent with global longitudinal strain of –19 percent, representing a 25 percent reduction in strain from baseline (Figure 2).

Examination

The patient presented with vital signs of BP 105/69, HR 85 and RR 12. She appeared thin but in no acute distress. Her lungs were normal and her heart was in regular rhythm. S1 and S2 were normal. No gallops or murmurs were appreciated. The abdomen was soft and non-tender. Extremities were normal.

Treatment

The patient was started on carvedilol at a dosage of 3.125 mg orally twice daily. Three months after carvedilol initiation, her global longitudinal strain improved to –22 percent (Figure 3). Her LVEF remained at 58 percent.

Discussion: Strain echo can target patients for early cardioprotection

Trastuzumab is a humanized monoclonal antibody that has revolutionized the treatment of HER-2-positive breast cancer, yielding a 34 percent improvement in overall survival rate.

However, a recent Cochrane meta-analysis of randomized clinical trials demonstrated a fivefold increased risk of congestive heart failure in women receiving trastuzumab-based regimens.

Advertisement

Strain echocardiography is a new technology that allows detection of small changes in ventricular function. A relative drop of >10 percent in global longitudinal strain can help identify those patients who will have a drop in their ejection fraction three months later (sensitivity, 78 percent; specificity, 79 percent; negative predictive value, 93 percent).

Identifying subclinical left ventricular dysfunction in trastuzumab recipients offers the potential to intervene early with cardioprotective therapies with the intent to prevent a decline in left ventricular function and subsequent progression to systolic heart failure. This allows patients to remain on lifesaving chemotherapy — and avoid a choice between cancer and heart disease.

Advertisement

Related Articles

20-HVI-2034260_impella-heart-illustration_650x450
Preemptive Hemodynamic Support for Improving the Safety and Efficacy of VT Ablation

How we’re using a new multidisciplinary approach to broaden the benefits of ablation

20-HVI-2026375_machine-learning_650x450
Study Shows Machine Learning’s Potential to Predict Cancer Therapy-Related Cardiac Risk

Models developed with promising accuracy and generalizability to clinical practice

20-HVI-1961366_home-blood-pressure-monitor-_650x450
Digital Remote Blood Pressure Management: Has Its Time Come?

Keys to success include a team-based approach and integration into clinical workflow

20-HVI-1941484_robotic-myectomy-mitral-valve-repair_650x450
Introducing Robotic Myectomy With Mitral Valve Repair

A minimally invasive, single-incision approach to two coexisting problems

19-HRT-5504-Khatri-CQD-2
Robotics in the Cardiac Cath Lab

A long-overdue technology is poised to reshape practice

Ad